XLPE Insulation
Airmaster Thermal Insulation – CROSS LINKED POLYOLEFIN FOAM
Fire resistance & low toxic smoke emission
Environment friendly
Excellent thermal efficiency
Cost saving
Zero water vapor permeability and low water absorption rate
Cross Linked Polyolefin Foam
XLPE is chemically crosslinked Polyolefin foam is extremely fine closed cells foam and smooth skins on both sides. It is light in weight, flexible, soft in touch, strong and tough in physical properties, resilient and resistant to moisture, chemicals and extreme temperature. It typically offers superior thermal stability and insulating properties improved dimensional consistency and stability over a wide range of fabrication methods and end-user’s conditions. It is easy to work in fabricating and thermoforming. XLPE foams work well in the building and construction industry where thermal insulation, sound and vibration are critical, due to its low moisture permeability and high buoyancy.
XLPE Properties:
- Resilient
- Excellent buoyancy
- Good thermal insulator
- Excellent strength and shock absorption
- Low water absorption
- Impervious to mildew, mold, rot, and bacteria
- Excellent chemical resistance
- Nontoxic and contains no CFCs, HCFCs, or hydrocarbon blowing agents
- Superior Flame Spread (FSI) and Smoke Developed (SDI) Index
XLPE Applications
Automobile / Train
Roofing
HVAC Ducting &
Chilled Water Plping
Insulated Roofing Panel
Flooring
Water Storage Tanks
Building Envelope
Technical Specification
PROPERTIES | VALUE | TEST METHOD |
Material | Chemically Cross link Polyolefin foam | ———– |
Cell structure | Closed cell | Digital Analysis |
Thickness | 2mm to 50mm | (Based on customer request) |
Temperature range | -70 to 100° C | |
Density | 27 kg/m3 – 35 kg /m3 | ASTM D 1667 |
Thermal Conductivity(W/Mk) | @ 230c (mean temperature)0.034 @ 400c (mean temperature)0.038 |
ASTM C 518-04 |
Water vapour permeability mu value | μ>10.000 | |
Water Absorption by Volume | 0.00065g/cm2 | ASTM C 518-04 |
Fire Rating | UL 94 : HF-1 Flammability Extent of Burning : 38mm (KS M3809:1997) Flammability Time of Burning : 0 Sec (KS M3809:1997) ASTME 84 : Flame Spread Index <25 Smoke Developed Index < 50 |
BS 476 Part 6&7 : Class 1 |
Smoke Toxicity | Non toxic , HCN Free | |
Overall Toxicity in fire | None : 99% CO2 and H2O upon Complete combustion. Force 10% 0.045 – 0.045 N/mm2 |
ABD 0031 |
Pressure Resistance | Force 20% 0.045 – 0.055 N/mm2 Force 50% 0.045 – 0.080 N/mm2 |
ISO844 DIN53577 |
Tear Strength | Good | DIN53577 |
Ozone Resistance | Excellent | ———– |
Chemical Resistance | Excellent | ASTM 543 |
UV and Water Resistance | Excellent | ISO4892-2 |
Resistance to Fungi: | Zero Growth | ASTM G21 |